Technical Specification
ECG
- Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
- Lead selection: I, II, III, avR, avL, avF, V,
- Waveform: 2 ch
- Lead mode: 3 Leads (R, L, F or RA, LA, LL)
- Lead selection: I, II, III,
- Waveform: 1 ch
- Gain: ?2.5mm/mV, ?5.0mm/mV, ?10mm/mV, ?20mm/mV, auto
Heart Rate and Alarm
- Range
- Adult: 15 ~ 300 bpm
- Neo/Ped: 15 ~ 350 bpm
- Accuracy: ? 1% or ? 1bpm, which great
- Resolution: 1 bpm
- Sensitivity: > 200 (uV P-P)
- Differential Input Impedance: > 5 M?
- CMRR
- Monitor: > 105 dB
- Operation: > 105 dB
- Diagnosis: > 85 dB
- Electrode offset potential: ?300mV
- Leakage Current: < 10 uA
- Baseline Recovery: < 3 S after Defi.
- ECG Signal Range: ?8 m V (Vp-p)
- Bandwidth
- Surgery: 1 ~ 15 Hz
- Monitor: 0.5 ~ 35 Hz
- Diagnostic: 0.05 ~ 100 Hz
- Calibration Signal: 1 (mV p-p), Accuracy: ?5%
- ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
- ARR Detecting
- Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm: Available
- Review: Available
Respiration
- Method: Impedance between R-F (RA-LL)
- Differential Input Impedance: >2.5 M?
- Measuring Impedance Range: 0.3~5.0?
- Base line Impedance Range: 0 ? 2.5 K?
- Bandwidth: 0.3 ~ 2.5 Hz
- Resp. Rate
- Measuring and Alarm Range
- -Adult: 0 ~ 120 rpm
- -Neo/Ped: 0 ~ 150 rpm
- Resolution: 1 rpm
- Accuracy: ?2 rpm
- Apnea Alarm: 10 ~ 40 S
NIBP
- Method: Oscillometric
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
- 120, 180, 240,480 (Min)
- Measuring Period in STAT Mode: 5 Min
- Pulse Rate Range: 40 ~ 240 bpm
- Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
- SYS: 40 ~ 270 mmHg
- DIA: 10 ~ 215 mmHg
- MEAN: 20 ~ 235 mmHg
Pediatric Mode
- SYS: 40 ~ 200 mmHg
- DIA: 10 ~ 150 mmHg
- MEAN: 20 ~ 165 mmHg
Neonatal Mode
- SYS: 40 ~ 135 mmHg
- DIA: 10 ~ 100 mmHg
- MEAN: 20 ~ 110 mmHg
- Resolution Pressure: 1mmHg
- Accuracy Pressure Maximum Mean error: ?5mmHg
- Maximum Standard deviation: ?8mmHg
- Overpressure Protection
- Adult Mode: 297?3 mmHg
- Pediatric Mode: 240?3 mmHg
- Neonatal Mode: 147?3 mmHg
SpO2
- Measuring Range: 0 ~ 100 %
- Alarm Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: 70% ~ 100% ?2 %; 0% ~ 69% unspecified
- Actualization interval: about 1 Sec.
- Alarm Delay: 10 Sec.
- Pulse Rate
- Measuring and Alarm Range: 20~300bpm
- Resolution: 1bpm
- Accuracy: ?2bpm
Temperature
- Channel: 2
- Measuring and Alarm Range: 0 ~ 50 ?C
- Resolution: 0.1?C
- Accuracy: ?0.1?C
- Actualization interval: about 1 Sec.
- Average Time Constant:<10 Sec.
IBP(optional)
- Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
- Measuring and alarm range
- ART: 0 ~ 300 mmHg
- PA: -6 ~ 120 mmHg
- CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
- P1/P2: -10 ~ 300 mmHg
- Press Sensor
- Sensitivity: 5 uV/V/mmHg
- Impedance: 300-3000?
- Resolution: 1 mmHg
- Accuracy: ?2% or ?1mmHg, which great
- Actualization interval: about 1 Sec
Standard Packing List
- 5-lead ECG cable (including RESP)
- Adult finger SpO2 sensor
- Adult NIBP cuff
- NIBP extension tube
- TEMP sensor
- AC power adaptor
- ECG electrodes
- Operation instruction
Optional Function
Internal Recorder, IBP, EtCO2, Central Monitoring System, Touch Screen, VGA, Neonate SPO2