Features
- 15? TFT LCD screen displays the Ventilation parameters, Alarming information, and oscillograms, make every operation more easily.
- Multiple ventilation modes, suitable for ICU, emergency department and operation room etc:(PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL)
- 5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
- Humidifier can heat and wet breathing gas,makes it comfortable for patient to breathe
- Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.
- Nebulization make medicine into small liquid and particle, easier and quicker for patient to breathe in.
- High temperature resistance breathing circuit is reusable and anti-pollution.
?
Safety
- 14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
- Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration
- Easy to move with four casters, easy to stop with two brakes
- Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
- Compact long life internal battery can provide emergency power, avoid risk of patient
- Self-check before operation, eliminate system mistake
Technical Specifications
NAME | PARAMETER |
Ventilation modes | PRVC,APRV,DUOLEVEL,V-SIMV,P-SIMV,IPPV,A/C,PCV,PSV,SPONT/CPAP, SIGH, MANUAL |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0~2000mL |
Frequency (Freq) | 1min~100min |
Oxygen concentration | 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O~?40 cmH2O |
Pressure Triggering Sensitivity (Ptr) | -20cmH2O~20cmH2O (Based on PEEP) |
Flow Triggering Sensitivity (Ftr) | 0.5L/min~30L/min |
Pressure Control | 5cmH2O~80cmH2O |
Pressure Support | 0cmH2O~80cmH2O |
SIGH | 0(off) 1/100~5/100 |
Apnea Ventilation | OFF, 5s~60s |
Pressure Limit | 20cmH2O~100cmH2O |
Monitored Parameters | |
Frequency (Freq) | 0 /min~?100 /min |
Tidal volume(Vt) | 0 mL~?2500 mL |
MV | 0L/min~99L/min |
Airway pressure | 0cmH2O~100cmH2O |
Dynamic Lung Compliance Testing | 1mL/cmH2O~1000mL/cmH2O |
Oxygen Concentration | 15%-100% |
Alarm and protection?? | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ?11.3?0.3V |
No tidal volume | No tidal volume within 6s |
High?Minute Volume?alarmLow?Minute Volume?alarm | 5L/min-99L/min1L/min-30L/min |
High Airway pressure alarmLow?Airway pressure alarm
High oxygen?concentration?alarm Low oxygen?concentration?alarm |
20cmH2O-100cmH2O0cmH2O-20cmH2O
19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warningFan error
Oxygen deficit |
5-60sShow on screen
Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | 220V?22V |
Power frequency | 50Hz?1Hz |
Input power | 900VA(with air compressor)250VA(without air compressor) |
Oscillogram | |
P-T | Pressure Time |
F-T | Flow-Time |
V-T | Volume Time |
P-V Loop | Pressure-Volume Loop |
F-V Loop | Flow Volume Loop |
P-F Loop | Pressure-Flow Loop |