Glycated Hemoglobin Analyzer
Automatic Glycated Hemoglobin HbA1c Analyzer
Product Description
Accurate Principle of Methodology Adopts classical and accurate principle of methodology ? Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test on line, and obtain the correct area percentage with integration.
- Accurate separation 4-gradient elution The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine elution process produced by high and low concentration mixture. ?High Separation Liquid Chromatographic Column High separation liquid chromatographic column made of imported resin with volume of ? 9mm x 45mm and weight of 2.5g which is 15 ? 20 times greater than general micro chromatographic column. High efficiency chromatographic column for 300 tests ensure the accuracy of test results. ?High Sensitivity 415nm LED Integral Photometer High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve. ?Supply with Original Calibrator The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration. ?Precision Chromatographic Column and Thermostatic Apparatus Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results.
- Real-time summarized chromatogram, Intelligence process detection The advanced embedded micro processing system + intelligence control software can really display testing curve and the real redisplay of testing process and can monitor and alarm for test results, absorbency, signal potential, peak time and reagent consumption. It can be operated with high proficiency. ?Full-auto 25-position Sample Turntable, Optional Selection of Batch Test or Emergency Test With full-auto 25-position sample turntable, it is unnecessary to use complicated rank sampling device and built-in hemolysis device. Batch test can be automatically carried out. Emergency test can be carried out at any time. ?Full-open Structure, perfect flow path, low failure and easy maintenance Full-open structure, Perfect solenoid valve flow path, it is unnecessary to use complicated sample mechanical 6-way and rotating distribution control valve. It is reliable for use and easy for maintenance. ?5ul whole blood, for both labs and clinics 5ul whole blood, both venous blood and peripheral finger blood can be tested, suitable for labs for batch tests and also suitable for clinics for providing test results immediately. Both venous blood and peripheral finger blood can be tested. ?With gas solution and bubble-removal technology, the error can be eliminated overall. Since the instrument is equipped with reagent solvability gas eliminating device and applies the cuvette bubble auto detection eliminating technology, the air bubbles which affect the test results can be eliminated overall without the complicated degassing device. ?Saccharification concentration, area percentage and average glucose can be synchronously reported. The instrument can output the data including IFCC concentration value, NGSP area percentage and ADAG average glucose on the test report synchronously to meet the requirement of world standardization. It may memorize 1000 test curve reports and is equipped with RS232 communication interface and can connect directly to HIS/LIS system.