Showing all 13 results

Dental Cone Beam Computed Tomography System AM-ADM-3000A

  1. Clinical Application

Oral and maxillofacial cone beam computed tomography equipment

(dental CT) with 12cmX15cm flat panel detector, can be widely used in

oral and maxillofacial surgery, orthodontics, orthognathic surgery,

implant, dental, temporomandibular joint Preoperative and postoperative.

Dental X-ray Unit ADM-10B

  1. Specifications

Classification: Electrometrical, Class I, Type B

Power supply: 220V±10%, 50Hz, 1kVA

Tube voltage: 60KVp

Tube current: 8mA

Focus size: 1.5mm

Total filtration: 2.5mmAL

Exposure time: 0.2 to 4 sec

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Optional: Tube current: 0.5mA

Focus size: 0.8mm

Dental X-ray Unit AM-ADM-10B

-The microprocessor-controlled timer brings high-tech X-ray imaging at your fingertips.

-The control panel allows on accurate and fast exposure time selection while protecting the head during X-ray examinations.

Dental X-ray Unit AM-ADM-10D

Specifications

Classification: Electrometrical, Class I, Type B

Power supply: 220V±10%, 50Hz, 1kVA

Tube voltage: 60KVp

Tube current: 8mA

Focus size: 1.5mm

Total filtration: 2.5mmAL

Exposure time: 0.2 to 4 sec

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Optional: Tube current: 0.5mA

Focus size: 0.8mm

Dental X-ray Unit AM-ADM-10D

  1. Specifications

Classification: Electrometrical, Class I, Type B

Power supply: 220V±10%, 50Hz, 1kVA

Tube voltage: 60KVp

Tube current: 8mA

Focus size: 1.5mm

Total filtration: 2.5mmAL

Exposure time: 0.2 to 4 sec

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Optional: Tube current: 0.5mA

Focus size: 0.8mm

Digital Dental X-ray Sensor AM-DS530

Description:

Material: APS

Sensing area:30X20mm (600mm2)

Sensor Pixels:3.2 million pixels

Pixel size:19x19um

Resolution:> 20 lp / mm

Gray scale:12 bit

Life:> 100000 times

Dimensions:37.0×24.5×5.5mm

Line length (Material – Polyurethane):3m

Connection:USB standard

Handheld High Frequency Dental X-ray Unit AM-ADM-10P

Specifications

Frequency: 32KHZ

Tube voltage: 60KV

Tube current: 1.5mA

Exposure time: 0.02-4sec

Distance from skin to cone: 130mm

Tube focus: 0.3mm*0.3mm

Output voltage: DC16.8V

Battery: DC14.8V, 6400mAh

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Ambient temperature: 5℃~40℃

Relative temperature: <75%RH

Optional color: grey, pink, light green

Handheld High Frequency Dental X-ray Unit AM-ADM-10P

  1. Specifications

Frequency: 32KHZ

Tube voltage: 60KV

Tube current: 1.5mA

Exposure time: 0.02-4sec

Distance from skin to cone: 130mm

Tube focus: 0.3mm*0.3mm

Output voltage: DC16.8V

Battery: DC14.8V, 6400mAh

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Ambient temperature: 5℃~40℃

Relative temperature: <75%RH

Optional color: grey, pink, light green

High Frequency Dental X-ray Unit AM-ADM-10A

Specifications

Power supply: AC220V±10%

or AC110V±10%, 50/60HZ

Frequency: 200KHZ

Tube voltage: 70KV

Tube current: 8mA

Focus size: 0.8mm

Total filtration: 2.5mmAL

Exposure time: 0.02-4sec

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

High Frequency Dental X-ray Unit AM-ADM-10A

  1. Specifications

Power supply: AC220V±10%

or AC110V±10%, 50/60HZ

Frequency: 200KHZ

Tube voltage: 70KV

Tube current: 8mA

Focus size: 0.8mm

Total filtration: 2.5mmAL

Exposure time: 0.02-4sec

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Mobile High Frequency Dental X-ray Unit AM-ADM-10P

Specifications

Frequency: 32KHZ

Tube voltage: 60KV

Tube current: 1.5mA

Exposure time: 0.02-4sec

Distance from skin to cone: 130mm

Tube focus: 0.3mm*0.3mm

Output voltage: DC16.8V

Battery: DC14.8V, 6400mAh

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Ambient temperature: 5℃~40℃

Relative temperature: <75%RH

Optional color: grey, pink, light green

ADM-10P Mobile X-ray Machine is with remote control exposure function

Mobile High Frequency Dental X-ray Unit AM-ADM-10P

  1. Specifications

Frequency: 32KHZ

Tube voltage: 60KV

Tube current: 1.5mA

Exposure time: 0.02-4sec

Distance from skin to cone: 130mm

Tube focus: 0.3mm*0.3mm

Output voltage: DC16.8V

Battery: DC14.8V, 6400mAh

Leak radiation: Outside one meter≤0.002mGy/h

(National standard: 0.25mGy/h)

Ambient temperature: 5℃~40℃

Relative temperature: <75%RH

Optional color: grey, pink, light green

ADM-10P Mobile X-ray Machine is with remote control exposure function

ORAL PANORAMIC X-RAY UNIT AM-MSQJ2000-I

Features

It is designed on the principles of X-ray drum curvature tomography, adopts a high-frequency and high-voltage generator and a special dental X-ray tube and can be lifted and lowered manually and locked electromagnetically, thus ensuring it a small focus when radiographing so as to obtain clear images. Furthermore, according to the figures of patients, the minimum radiation level of the unit can be chosen to take pictures for children and adults. Such human-oriented design protects the health of medical personnel and patients.